To reset your ToneDexter II to factory default settings:

  • Be aware that all WaveMap data will be deleted, so back them up first by connecting to the web management page and hitting the Backup button. Save the .bak file to a convenient location.
  • The factory reset option is only available from V3.3 software onward. If you have a version older than that, update the software from the web management page if possible. If this is not possible, then there is a back door method to restore and update the unit using this V2.7.uf2 file.
    • Connect a USB cable
    • Press and hold the red boot button on the rear for about 2 second and let go. A removable drive named RPI-RP2 will appear on your computer.
    • Drag the .uf2 file to this drive. Say OK to any warnings. The removable drive will disappear once transfer is complete. Ignore the eject warning.
  • Once you’ve got version 2.7 installed, go to the web management page and update to V3.3 (or the latest version available) by clicking the update button. If you haven’t yet registered your ToneDexter, you’ll need to do that first.
  • Once you’ve updated to V3.3 or later, tap the red button on the rear to restart the unit, then press and hold the Aux In and Aux Out buttons while the spinning sprocket is displayed on startup. This will give you the option to confirm a factory reset.

 